| Assessment Year | 2010 |
|---|---|
| Principal Product | Soy Sauce |
| NAICS | 311941: Mayonnaise, Dressing, and Other Prepared Sauce Manufacturing |
| SIC | 2035: Pickled Fruits and Vegetables, Vegetable Sauces and Seasonings, and Salad Dressings |
| Sales Range | $10 M to 50M |
| # of Employees | 56 |
| Plant Area |
100,000
ft2
|
| Annual Production | 3,200
Tgal
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $145,749 | 2,241,600 |
kWh
|
$0.065 |
| Electricity Demand | $31,180 | 6,519 |
kW-mo/yr
|
$4.78 |
| Natural Gas | $196,679 | 228,083 |
MMBtu
|
$0.86 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $47,521 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,893 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $542 | - |
$542
5,605
kWh
|
- | - | |
| 02 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $1,765 | - | - | - | $1,765 | |
| 03 | 4.321: Optimize production lot sizes and inventories | $8,900 | $8,900 | - | $8,900 | - | |
| 04 | 2.4239: Eliminate or reduce compressed air usage | $8,987 | $5,125 |
$8,987
116,324
kWh
|
- | - | |
| 05 | 2.1113: Reduce combustion air flow to optimum | $3,131 | $2,861 |
$3,131
45,748
kWh
|
- | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,320 | $2,320 |
$2,320
29,982
kWh
|
- | - | |
| 07 | 2.4239: Eliminate or reduce compressed air usage | $5,397 | $11,734 |
$5,397
69,855
kWh
|
- | - | |
| 08 | 2.9114: Use solar heat to make electricty | $16,479 | $65,003 |
$16,479
218,700
kWh
|
- | - | |
| TOTAL RECOMMENDED | $47,521 | $95,943 |
$36,856
486,214
kWh
|
$8,900 | $1,765 | ||
| TOTAL IMPLEMENTED | $14,893 | $14,081 |
$5,993
81,335
kWh
|
$8,900 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs