Assessment Year | 2008 |
---|---|
Principal Product | Printers |
NAICS | 423690: Other Electronic Parts and Equipment Merchant Wholesalers |
SIC | 5065: Electronic Parts and Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 1,500 |
Plant Area |
202,800
ft2
|
Annual Production | 24,700
pieces
|
Production Hrs. Annual | 3,952
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $191,373 | 3,148,616 |
kWh
|
$0.061 |
Electricity Demand | $27,862 | 7,918 |
kW-mo/yr
|
$3.52 |
Electricity Fees | $7,773 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $252,888 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $29,018 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Increase in Production Savings |
---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $18,938 | $27,195 |
$18,938
12,487
kWh
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,213 | - |
$1,213
17,826
kWh
|
- | |
03 | 2.4239: Eliminate or reduce compressed air usage | $6,256 | - |
$6,256
99,931
kWh
|
- | |
04 | 2.9113: Use solar heat for heat | $127,842 | $530,836 |
$127,842
1,898,208
kWh
|
- | |
05 | 2.4133: Use most efficient type of electric motors | $2,611 | $6,927 |
$2,611
29,841
kWh
|
- | |
06 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $89,250 | $7,000 | - | $89,250 | |
07 | 2.7135: Install occupancy sensors | $6,778 | $15,745 |
$6,778
47,709
kWh
|
- | |
TOTAL RECOMMENDED | $252,888 | $587,703 |
$163,638
2,106,002
kWh
|
$89,250 | ||
TOTAL IMPLEMENTED | $29,018 | $34,122 |
$29,018
160,085
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs