| Assessment Year | 2008 |
|---|---|
| Principal Product | LED Substrates and Laser Crystals |
| NAICS | 327213: Glass Container Manufacturing |
| SIC | 3221: Glass Containers |
| Sales Range | $10 M to 50M |
| # of Employees | 68 |
| Plant Area |
74,000
ft2
|
| Annual Production | 1,000
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Washington |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $665,079 | 15,420,160 |
kWh
|
$0.043 |
| Electricity Demand | $166,523 | 29,421 |
kW-mo/yr
|
$5.66 |
| Electricity Fees | $52,419 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $81,484 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $2,818 | $2,800 |
$2,818
44,019
kWh
|
- | - | |
| 02 | 2.3212: Optimize plant power factor | $20,000 | $87,500 | - | $20,000 | - | |
| 03 | 3.5142: Treat and reuse equipment cleaning solutions | $2,400 | - |
$2,400
26,100
kWh
|
- | - | |
| 04 | 4.521: Clear and rent existing space | $24,000 | - | - | - | $24,000 | |
| 05 | 2.4131: Size electric motors for peak operating efficiency | $32,266 | $3,000 |
$32,266
2,343
kWh
|
- | - | |
| TOTAL RECOMMENDED | $81,484 | $93,300 |
$37,484
72,462
kWh
|
$20,000 | $24,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs