| Assessment Year | 2004 |
|---|---|
| Principal Product | Dried & Frozen Apples |
| NAICS | 311411: Frozen Fruit, Juice, and Vegetable Manufacturing |
| SIC | 2037: Frozen Fruits, Fruit Juices, and Vegetables |
| Sales Range | $50 M to 100M |
| # of Employees | 175 |
| Plant Area |
176,000
ft2
|
| Annual Production | 25,623
ton
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Washington |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $139,338 | 12,598,141 |
kWh
|
$0.011 |
| Electricity Demand | $90,695 | 29,508 |
kW-mo/yr
|
$3.07 |
| Electricity Fees | $12,388 | - |
|
- |
| Natural Gas | $1,132,856 | 488,720 |
MMBtu
|
$2.32 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $30,420 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $26,620 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $11,420 | $6,400 | - | - | $11,420 | |
| 02 | 2.4133: Use most efficient type of electric motors | $5,500 | $1,900 |
$3,600
327,100
kWh
|
$1,900
-
kW-mo/yr
|
- | |
| 03 | 2.4322: Use or replace with energy efficient substitutes | $9,700 | $49,100 |
$6,700
604,200
kWh
|
$3,000
-
kW-mo/yr
|
- | |
| 04 | 2.2621: Modify refrigeration system to operate at a lower pressure | $3,800 | - |
$3,800
343,000
kWh
|
- | - | |
| TOTAL RECOMMENDED | $30,420 | $57,400 |
$14,100
1,274,300
kWh
|
$4,900
-
kW-mo/yr
|
$11,420 | ||
| TOTAL IMPLEMENTED | $26,620 | $57,400 |
$10,300
931,300
kWh
|
$4,900
-
kW-mo/yr
|
$11,420 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs