Assessment Year | 2003 |
---|---|
Principal Product | Door Frame Parts |
NAICS | 321911: Wood Window and Door Manufacturing |
SIC | 2431: Millwork |
Sales Range | $50 M to 100M |
# of Employees | 260 |
Plant Area |
n/a
|
Annual Production | 27,100,000
thousand feet
|
Production Hrs. Annual | 0
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $292,292 | 7,745,142 |
kWh
|
$0.038 |
Electricity Demand | $97,026 | 290,352 |
kW-mo/yr
|
$0.33 |
Electricity Fees | $7,867 | - |
|
- |
Natural Gas | $57,446 | 8,607 |
MMBtu
|
$6.67 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $585,730 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $50,680 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.621: Use fixtures to reduce machine changeout times | $508,000 | $28,000 | - | - | - | - | $508,000 | |
02 | 2.4323: Use optimum size and capacity equipment | $9,000 | $8,100 |
$9,000
246,000
kWh
|
- | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $21,800 | $21,600 |
$15,200
415,000
kWh
|
$6,600
-
kW-mo/yr
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,100 | $13,000 |
$11,500
314,000
kWh
|
$1,600
-
kW-mo/yr
|
- | - | - | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $27,050 | $98,000 |
$12,609
203,800
kWh
|
$6,013
-
kW-mo/yr
|
$406 | $8,022 | - | |
06 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $6,780 | $26,000 |
$(-2,870.0)
(-92,500)
kWh
|
- | $1,440 | $8,210 | - | |
TOTAL RECOMMENDED | $585,730 | $194,700 |
$45,439
1,086,300
kWh
|
$14,213
-
kW-mo/yr
|
$1,846 | $16,232 | $508,000 | ||
TOTAL IMPLEMENTED | $50,680 | $68,700 |
$32,830
882,500
kWh
|
$8,200
-
kW-mo/yr
|
$1,440 | $8,210 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs