| Assessment Year | 2003 |
|---|---|
| Principal Product | Granola, Tea |
| NAICS | 311230: Breakfast Cereal Manufacturing |
| SIC | 2043: Cereal Breakfast Foods |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
67,445
ft2
|
| Annual Production | 15,400,000
lb
|
| Production Hrs. Annual | 5,375
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $55,879 | 1,237,352 |
kWh
|
$0.045 |
| Electricity Demand | $16,997 | 3,679 |
kW-mo/yr
|
$4.62 |
| Electricity Fees | $1,820 | - |
|
- |
| Natural Gas | $86,395 | 13,345 |
MMBtu
|
$6.47 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,218 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,887 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.8112: Combine utility meters | $3,901 | $7,500 | - | - | $3,901 | - | - | |
| 02 | 2.4239: Eliminate or reduce compressed air usage | $307 | - |
$307
7,128
kWh
|
- | - | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $743 | $26 |
$582
13,532
kWh
|
$161
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $437 | $500 |
$365
8,491
kWh
|
$72
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.2511: Insulate bare equipment | $742 | $1,320 | - | - | - |
$742
-
MMBtu
|
- | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $688 | $2,800 |
$544
12,632
kWh
|
$144
-
kW-mo/yr
|
- | - | - | |
| 07 | 4.513: Re-arrange equipment layout to reduce labor costs | $400 | $1,970 | - | - | - | - | $400 | |
| TOTAL RECOMMENDED | $7,218 | $14,116 |
$1,798
41,783
kWh
|
$377
-
kW-mo/yr
|
$3,901 |
$742
-
MMBtu
|
$400 | ||
| TOTAL IMPLEMENTED | $1,887 | $2,496 |
$1,254
29,151
kWh
|
$233
-
kW-mo/yr
|
- | - | $400 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs