| Assessment Year | 2002 |
|---|---|
| Principal Product | Hardwood Plywood |
| NAICS | 321211: Hardwood Veneer and Plywood Manufacturing |
| SIC | 2435: Hardwood Veneer and Plywood |
| Sales Range | $50 M to 100M |
| # of Employees | 245 |
| Plant Area |
n/a
|
| Annual Production | 138,000,000
thousand feet
|
| Production Hrs. Annual | 0
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $313,582 | 9,005,814 |
kWh
|
$0.035 |
| Electricity Demand | $56,946 | 16,656 |
kW-mo/yr
|
$3.42 |
| Electricity Fees | $22,518 | - |
|
- |
| Natural Gas | $1,152,518 | 261,156 |
MMBtu
|
$4.41 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $165,429 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $153,329 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1133: Adjust burners for efficient operation | $104,400 | $150 | - | - |
$104,400
-
MMBtu
|
|
| 02 | 2.4322: Use or replace with energy efficient substitutes | $6,010 | $135 |
$5,270
151,000
kWh
|
$740
-
kW-mo/yr
|
- | |
| 03 | 2.4131: Size electric motors for peak operating efficiency | $1,720 | $1,000 |
$1,320
37,800
kWh
|
$400
-
kW-mo/yr
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $41,000 | $41,000 |
$36,000
1,040,000
kWh
|
$5,000
-
kW-mo/yr
|
- | |
| 05 | 2.5125: Size air handling grills/ duct/s coils to minimize air resistance | $9,530 | $73,800 |
$8,010
230,000
kWh
|
$1,520
-
kW-mo/yr
|
- | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,570 | $6,080 |
$2,160
62,000
kWh
|
$410
-
kW-mo/yr
|
- | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $199 | - |
$167
4,800
kWh
|
$32
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $165,429 | $122,165 |
$52,927
1,525,600
kWh
|
$8,102
-
kW-mo/yr
|
$104,400
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $153,329 | $42,285 |
$42,757
1,233,600
kWh
|
$6,172
-
kW-mo/yr
|
$104,400
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||