Assessment Year | 2002 |
---|---|
Principal Product | MDF |
NAICS | 321219: Reconstituted Wood Product Manufacturing |
SIC | 2493: Reconstituted Wood Products |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
n/a
|
Annual Production | 1,000,000
thousand feet
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,534,529 | 84,246,000 |
kWh
|
$0.018 |
Electricity Demand | $353,847 | 2,067,168 |
kW-mo/yr
|
$0.17 |
Natural Gas | $2,727,629 | 719,286 |
MMBtu
|
$3.79 |
LPG | $43,467 | 4,896 |
MMBtu
|
$8.88 |
Fuel Oil #2 | $20,230 | 3,846 |
MMBtu
|
$5.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $2,075,750 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,015 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Energy Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $1,195,313 | $104,295 | - | - | - | - | $(-180,687.0) | - | $1,376,000 | |
02 | 4.441: Install automatic packing equipment | $484,000 | $420,000 | - | - | - | $400,000 | - | $84,000 | - | |
03 | 2.6242: Minimize operation of equipment maintained in standby condition | $121,380 | $120,000 | n/a |
$121,000
3,380,000
kWh
|
$380
-
kW-mo/yr
|
- | - | - | - | - |
04 | 4.111: Add equipment/ operators to reduce production bottleneck | $190,600 | $553,000 |
$248,100
6,936,000
kWh
|
$30,100
-
kW-mo/yr
|
$(-4,600.0)
-
MMBtu
|
- | - | $(-83,000.0) | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,015 | - |
$2,600
72,850
kWh
|
$415
-
kW-mo/yr
|
- | - | - | - | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,764 | $18,975 |
$6,697
187,596
kWh
|
$1,067
-
kW-mo/yr
|
- | - | - | - | - | |
07 | 2.4322: Use or replace with energy efficient substitutes | $73,678 | $282,688 |
$63,538
1,779,763
kWh
|
$10,140
-
kW-mo/yr
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $2,075,750 | $1,498,958 |
$441,935
12,356,209
kWh
|
$42,102
-
kW-mo/yr
|
$(-4,600.0)
-
MMBtu
|
$400,000 | $(-180,687.0) | $1,000 | $1,376,000 | ||
TOTAL IMPLEMENTED | $3,015 | - |
$2,600
72,850
kWh
|
$415
-
kW-mo/yr
|
- | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Energy Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs