Assessment Year | 2002 |
---|---|
Principal Product | window glass |
NAICS |
n/a
|
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
n/a
|
Annual Production | 7,950
thousand feet
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $698,498 | 12,333,687 |
kWh
|
$0.057 |
Electricity Demand | $21,616 | 54,036 |
kW-mo/yr
|
$0.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $60,170 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $25,584 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $26,500 | - |
$26,500
467,900
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,232 | - |
$7,232
127,720
kWh
|
- | - | |
03 | 2.6121: Reduce hot water temperature to the minimum required | $6,232 | $900 |
$6,232
110,058
kWh
|
- | - | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,086 | $19,050 | n/a |
$7,763
137,088
kWh
|
$323
-
kW-mo/yr
|
- |
05 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $2,731 | $1,800 |
$2,044
36,108
kWh
|
- | $687 | |
06 | 2.4133: Use most efficient type of electric motors | $9,389 | $26,990 |
$9,356
165,210
kWh
|
$33
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $60,170 | $48,740 |
$59,127
1,044,084
kWh
|
$356
-
kW-mo/yr
|
$687 | ||
TOTAL IMPLEMENTED | $25,584 | $29,690 |
$24,864
439,096
kWh
|
$33
-
kW-mo/yr
|
$687 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs