Assessment Year | 2002 |
---|---|
Principal Product | Hops pellets |
NAICS |
n/a
|
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
n/a
|
Annual Production | 14,200,000
lb
|
Production Hrs. Annual | 3,400
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $185,166 | 4,700,017 |
kWh
|
$0.039 |
Electricity Demand | $47,434 | 15,108 |
kW-mo/yr
|
$3.14 |
Electricity Fees | $12,316 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $40,183 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,683 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2621: Modify refrigeration system to operate at a lower pressure | $20,500 | $66,000 |
$20,500
610,100
kWh
|
- | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $8,050 | $25,951 |
$7,519
223,326
kWh
|
$531
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,510 | $4,500 |
$3,470
33,823
kWh
|
$1,040
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,377 | $6,300 |
$3,746
95,057
kWh
|
$1,035
-
kW-mo/yr
|
$102 | $494 | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,746 | - |
$1,275
37,861
kWh
|
$471
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $40,183 | $102,751 |
$36,510
1,000,167
kWh
|
$3,077
-
kW-mo/yr
|
$102 | $494 | ||
TOTAL IMPLEMENTED | $19,683 | $36,751 |
$16,010
390,067
kWh
|
$3,077
-
kW-mo/yr
|
$102 | $494 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs