Assessment Year | 2001 |
---|---|
Principal Product | Culture Media |
NAICS |
n/a
|
SIC | 2836: Biological Products, Except Diagnostic Substances |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
n/a
|
Annual Production | 3,072
Tgal
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $28,729 | 685,716 |
kWh
|
$0.042 |
Electricity Demand | $4,459 | 1,956 |
kW-mo/yr
|
$2.28 |
Natural Gas | $25,799 | 4,002 |
MMBtu
|
$6.45 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $334,057 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $334,057 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 4.421: Modify current incentive program | $289,800 | $26,680 | - | - | - | $289,800 | - | - | - | - | |
02 | 3.4146: Change method of deionized water production | $29,980 | $20,000 |
$(-128.0)
(-3,614)
kWh
|
$(-52.0)
-
kW-mo/yr
|
- | - | - | - | $30,160 | - | |
03 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $6,790 | $4,721 | - | - | - | - | - | - | - | $6,790 | |
04 | 2.1113: Reduce combustion air flow to optimum | $5,384 | $3,000 | - | - |
$5,384
-
MMBtu
|
- | - | - | - | - | |
05 | 2.7124: Make a practice of turning off lights when not needed | $2,103 | $590 |
$1,647
46,644
kWh
|
- | - | - | $38 | $418 | - | - | |
TOTAL RECOMMENDED | $334,057 | $54,991 |
$1,519
43,030
kWh
|
$(-52.0)
-
kW-mo/yr
|
$5,384
-
MMBtu
|
$289,800 | $38 | $418 | $30,160 | $6,790 | ||
TOTAL IMPLEMENTED | $334,057 | $54,991 |
$1,519
43,030
kWh
|
$(-52.0)
-
kW-mo/yr
|
$5,384
-
MMBtu
|
$289,800 | $38 | $418 | $30,160 | $6,790 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs