Assessment Year | 2001 |
---|---|
Principal Product | Specialty SMT Products |
NAICS |
n/a
|
SIC | 3672: Printed Circuit Boards |
Sales Range | $10 M to 50M |
# of Employees | 125 |
Plant Area |
32,000
ft2
|
Annual Production | 72,000
pieces
|
Production Hrs. Annual | 6,032
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $53,693 | 1,312,720 |
kWh
|
$0.041 |
Electricity Demand | $9,720 | 39,252 |
kW-mo/yr
|
$0.25 |
Electricity Fees | $948 | - |
|
- |
Natural Gas | $4,882 | 655 |
MMBtu
|
$7.45 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $956,872 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $955,025 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 4.111: Add equipment/ operators to reduce production bottleneck | $187,500 | $18,000 | - | - | - | - | - | $187,500 | - | |
02 | 4.111: Add equipment/ operators to reduce production bottleneck | $290,325 | $250,000 | - | - | - | - | $(-4,985.0) | - | $295,310 | |
03 | 4.111: Add equipment/ operators to reduce production bottleneck | $108,900 | $60,000 | - | - | - | - | - | - | $108,900 | |
04 | 4.421: Modify current incentive program | $368,300 | $29,120 | - | - | - | $368,300 | - | - | - | |
05 | 2.8112: Combine utility meters | $1,079 | $3,000 | - |
$(-2,525.0)
-
kW-mo/yr
|
$3,604 | - | - | - | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $768 | - |
$647
15,819
kWh
|
$121
-
kW-mo/yr
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $956,872 | $360,120 |
$647
15,819
kWh
|
$(-2,404.0)
-
kW-mo/yr
|
$3,604 | $368,300 | $(-4,985.0) | $187,500 | $404,210 | ||
TOTAL IMPLEMENTED | $955,025 | $357,120 | - | - | - | $368,300 | $(-4,985.0) | $187,500 | $404,210 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Primary Product Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs