Assessment Year | 2000 |
---|---|
Principal Product | Plywood |
NAICS |
n/a
|
SIC | 2436: Softwood Veneer and Plywood |
Sales Range | $10 M to 50M |
# of Employees | 232 |
Plant Area |
175,000
ft2
|
Annual Production | 110,000
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Idaho |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $671,995 | 24,907,972 |
kWh
|
$0.027 |
Electricity Fees | $153,688 | - |
|
- |
Fuel Oil #6 | $94,938 | 15,643 |
MMBtu
|
$6.07 |
Wood | $38,250 | 79,200 |
MMBtu
|
$0.48 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,354 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $17,792 | $24,000 | n/a | - | - | $17,792 | - | - |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,330 | $44,000 | n/a |
$6,018
218,933
kWh
|
$312
-
kW-mo/yr
|
- | - | - |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,246 | $6,825 | n/a |
$3,508
127,784
kWh
|
$738
-
kW-mo/yr
|
- | - | - |
04 | 2.7134: Use photocell controls | $986 | $700 | n/a |
$719
26,084
kWh
|
- | - | $29 | $238 |
TOTAL RECOMMENDED | $29,354 | $75,525 |
$10,245
372,801
kWh
|
$1,050
-
kW-mo/yr
|
$17,792 | $29 | $238 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs