Assessment Year 1995
Principal Product Aircraft Nacelles
NAICS
n/a
SIC 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 135
Plant Area 120,000
ft2
Annual Production 2,500
pieces
Production Hrs. Annual 4,171
hrs
Location (State) Arkansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $230,081 2,706,038
kWh
Natural Gas $21,906 4,450
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $15,747 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $15,747

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4133: Use most efficient type of electric motors $1,968 $3,070 $1,968
38,687
kWh
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $1,299 $542 $1,299
13,482
kWh
-
03 2.7111: Reduce illumination to minimum necessary levels $1,404 $780 $1,404
15,533
kWh
-
04 2.4221: Install compressor air intakes in coolest locations $123 $100 - $123
-
MMBtu
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,192 $250 $6,192
60,961
kWh
-
06 2.3131: Reschedule plant operations or reduce load to avoid peaks $4,761 - $4,761
-
kWh
-
TOTAL RECOMMENDED $15,747 $4,742 $15,624
128,663
kWh
$123
-
MMBtu
TOTAL IMPLEMENTED $15,747 $4,742 $15,624
128,663
kWh
$123
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs