Assessment Year | 2000 |
---|---|
Principal Product | Frozen Onions |
NAICS |
n/a
|
SIC | 2037: Frozen Fruits, Fruit Juices, and Vegetables |
Sales Range | $5 M to 10M |
# of Employees | 40 |
Plant Area |
40,000
ft2
|
Annual Production | 30,100,000
lb
|
Production Hrs. Annual | 6,744
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $119,403 | 5,007,913 |
kWh
|
$0.024 |
Electricity Demand | $31,583 | 120,060 |
kW-mo/yr
|
$0.26 |
Natural Gas | $59,771 | 11,103 |
MMBtu
|
$5.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $188,175 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,823 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Other Energy Savings | Personnel Changes Savings | Primary Raw Material Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $3,523 | $6,600 | - | - | $3,523 | - | - | - | - | - | |
02 | 2.3413: Burn fossil fuel to produce steam to drive a steam turbine-generator and use steam exhaust for heat | $16,300 | $20,000 | - | - | - |
$37,500
-
MMBtu
|
$(-21,700.0)
-
MMBtu
|
- | - |
$500
-
Tgal
|
|
03 | 4.441: Install automatic packing equipment | $142,687 | $81,200 |
$(-1,525.0)
(-61,841)
kWh
|
$(-508.0)
-
kW-mo/yr
|
- | - | - | $144,720 | - | - | |
04 | 3.2176: Increase use of automation | $25,665 | $2,234 |
$(-185.0)
(-7,620)
kWh
|
$(-150.0)
-
kW-mo/yr
|
- | - | - | - | $26,000 | - | |
TOTAL RECOMMENDED | $188,175 | $110,034 |
$(-1,710.0)
(-69,461)
kWh
|
$(-658.0)
-
kW-mo/yr
|
$3,523 |
$37,500
-
MMBtu
|
$(-21,700.0)
-
MMBtu
|
$144,720 | $26,000 |
$500
-
Tgal
|
||
TOTAL IMPLEMENTED | $19,823 | $26,600 | - | - | $3,523 |
$37,500
-
MMBtu
|
$(-21,700.0)
-
MMBtu
|
- | - |
$500
-
Tgal
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs