Assessment Year | 1998 |
---|---|
Principal Product | PVC Pipe |
NAICS |
n/a
|
SIC | 3084: Plastics Pipe |
Sales Range | $50 M to 100M |
# of Employees | 60 |
Plant Area |
225,000
ft2
|
Annual Production | 73,000,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $383,643 | 9,688,453 |
kWh
|
$0.040 |
Electricity Demand | $57,201 | 173,028 |
kW-mo/yr
|
$0.33 |
Electricity Fees | $6,248 | - |
|
- |
Natural Gas | $28,300 | 5,520 |
MMBtu
|
$5.13 |
LPG | $12,644 | 1,933 |
MMBtu
|
$6.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $101,441 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $23,009 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $44,432 | $21,400 |
$44,432
1,334,701
kWh
|
- | - | - | - | - | |
02 | 2.8114: Change rate schedules or other changes in utility service | $2,060 | - | - | - | - | $2,060 | - | - | |
03 | 2.2511: Insulate bare equipment | $9,949 | $13,663 |
$9,949
251,172
kWh
|
- | - | - | - | - | |
04 | 3.1162: Use less wasteful packaging | $34,000 | $73,000 | - |
$1,200
-
lb
|
$15,500 | - | $17,300 | - | |
05 | 4.621: Use fixtures to reduce machine changeout times | $11,000 | $28,700 | - | - | - | - | - | $11,000 | |
TOTAL RECOMMENDED | $101,441 | $136,763 |
$54,381
1,585,873
kWh
|
$1,200
-
lb
|
$15,500 | $2,060 | $17,300 | $11,000 | ||
TOTAL IMPLEMENTED | $23,009 | $42,363 |
$9,949
251,172
kWh
|
- | - | $2,060 | - | $11,000 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs