ITAC Assessment: OR0328
ITAC logo
ITAC Assessment: OR0328
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1998
Principal Product Cast truck parts
NAICS
n/a
SIC 3321: Gray and Ductile Iron Foundries
Sales Range $10
M
to 50
M
# of Employees 65
Plant Area 50,000
ft2
Annual Production 3,521
ton
Production Hrs. Annual 5,200
hrs
Location (State) Oregon

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $170,510 5,087,046
kWh
Electricity Demand $92,353 27,843
kW-mo/yr
Electricity Fees $15,986 -
Natural Gas $91,725 21,379
MMBtu
LPG $10,560 966
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $35,164 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $21,914

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings LPG Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $18,828 $1,000 $15,350
461,020
kWh
$3,478
-
kW-mo/yr
- - - - -
02 2.3212: Optimize plant power factor $6,658 $37,600 - - $6,658 - - - -
03 2.2511: Insulate bare equipment $1,700 $5,385 - $(-10.0)
-
kW-mo/yr
- $1,710
-
MMBtu
- - -
04 2.6218: Turn off equipment when not in use $1,552 $8,650 $1,202
36,049
kWh
$350
-
kW-mo/yr
- - - - -
05 2.7124: Make a practice of turning off lights when not needed $1,386 - $675
20,223
kWh
- - - - $451 $260
06 2.1332: Convert combustion equipment to burn natural gas $5,040 $44,500 $(-410.0)
(-12,309)
kWh
- - $(-3,950.0)
-
MMBtu
$10,560
-
MMBtu
$(-1,160.0) -
TOTAL RECOMMENDED $35,164 $97,135 $16,817
504,983
kWh
$3,818
-
kW-mo/yr
$6,658 $(-2,240.0)
-
MMBtu
$10,560
-
MMBtu
$(-709.0) $260
TOTAL IMPLEMENTED $21,914 $6,385 $16,025
481,243
kWh
$3,468
-
kW-mo/yr
- $1,710
-
MMBtu
- $451 $260
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings LPG Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs