Assessment Year | 1998 |
---|---|
Principal Product | Cast truck parts |
NAICS |
n/a
|
SIC | 3321: Gray and Ductile Iron Foundries |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
50,000
ft2
|
Annual Production | 3,521
ton
|
Production Hrs. Annual | 5,200
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $170,510 | 5,087,046 |
kWh
|
$0.034 |
Electricity Demand | $92,353 | 27,843 |
kW-mo/yr
|
$3.32 |
Electricity Fees | $15,986 | - |
|
- |
Natural Gas | $91,725 | 21,379 |
MMBtu
|
$4.29 |
LPG | $10,560 | 966 |
MMBtu
|
$10.93 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $35,164 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,914 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,828 | $1,000 |
$15,350
461,020
kWh
|
$3,478
-
kW-mo/yr
|
- | - | - | - | - | |
02 | 2.3212: Optimize plant power factor | $6,658 | $37,600 | - | - | $6,658 | - | - | - | - | |
03 | 2.2511: Insulate bare equipment | $1,700 | $5,385 | - |
$(-10.0)
-
kW-mo/yr
|
- |
$1,710
-
MMBtu
|
- | - | - | |
04 | 2.6218: Turn off equipment when not in use | $1,552 | $8,650 |
$1,202
36,049
kWh
|
$350
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.7124: Make a practice of turning off lights when not needed | $1,386 | - |
$675
20,223
kWh
|
- | - | - | - | $451 | $260 | |
06 | 2.1332: Convert combustion equipment to burn natural gas | $5,040 | $44,500 |
$(-410.0)
(-12,309)
kWh
|
- | - |
$(-3,950.0)
-
MMBtu
|
$10,560
-
MMBtu
|
$(-1,160.0) | - | |
TOTAL RECOMMENDED | $35,164 | $97,135 |
$16,817
504,983
kWh
|
$3,818
-
kW-mo/yr
|
$6,658 |
$(-2,240.0)
-
MMBtu
|
$10,560
-
MMBtu
|
$(-709.0) | $260 | ||
TOTAL IMPLEMENTED | $21,914 | $6,385 |
$16,025
481,243
kWh
|
$3,468
-
kW-mo/yr
|
- |
$1,710
-
MMBtu
|
- | $451 | $260 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs