Assessment Year | 1998 |
---|---|
Principal Product | Storage Bins, Baghouses |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
42,000
ft2
|
Annual Production | 750,000
lb
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $26,659 | 967,761 |
kWh
|
$0.028 |
Electricity Demand | $18,557 | 4,346 |
kW-mo/yr
|
$4.27 |
Electricity Fees | $3,746 | - |
|
- |
Natural Gas | $10,415 | 1,893 |
MMBtu
|
$5.50 |
LPG | $2,654 | 270 |
MMBtu
|
$9.83 |
Other Gas | $1,576 | 14,331 |
MMBtu
|
$0.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,475 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,000 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.1192: Reduce scrap production | $22,000 | $12,480 | - | - | - |
$(-4,000.0)
-
lb
|
$26,000 | |
02 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $1,960 | $180 | - | - | - |
$1,960
-
lb
|
- | |
03 | 2.3212: Optimize plant power factor | $3,399 | $5,800 | - | - | $3,399 | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,116 | $1,000 |
$604
25,498
kWh
|
$512
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $28,475 | $19,460 |
$604
25,498
kWh
|
$512
-
kW-mo/yr
|
$3,399 |
$(-2,040.0)
-
lb
|
$26,000 | ||
TOTAL IMPLEMENTED | $22,000 | $12,480 | - | - | - |
$(-4,000.0)
-
lb
|
$26,000 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs