| Assessment Year | 1998 |
|---|---|
| Principal Product | Frozen Vegetables |
| NAICS |
n/a
|
| SIC | 2037: Frozen Fruits, Fruit Juices, and Vegetables |
| Sales Range | $10 M to 50M |
| # of Employees | 180 |
| Plant Area |
n/a
|
| Annual Production | 34,259,124
lb
|
| Production Hrs. Annual | 5,376
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $239,566 | 7,574,150 |
kWh
|
$0.032 |
| Electricity Demand | $85,699 | 22,296 |
kW-mo/yr
|
$3.84 |
| Electricity Fees | $8,830 | - |
|
- |
| Natural Gas | $41,718 | 9,035 |
MMBtu
|
$4.62 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $133,907 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,649 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.1191: Change procedures / equipment / operating conditions | $112,722 | $650,500 | - | - | - | - | - | - | $112,722 | |
| 02 | 2.2515: Use optimum thickness insulation | $1,740 | $4,421 |
$1,440
46,014
kWh
|
$300
-
kW-mo/yr
|
- | - | - | - | - | |
| 03 | 2.3212: Optimize plant power factor | $8,062 | $21,202 | - | - | $8,062 | - | - | - | - | |
| 04 | 2.4133: Use most efficient type of electric motors | $5,341 | $20,064 |
$4,089
130,715
kWh
|
$1,252
-
kW-mo/yr
|
- | - | - | - | - | |
| 05 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,035 | - |
$1,035
33,118
kWh
|
- | - | - | - | - | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,008 | $1,514 |
$987
31,653
kWh
|
$170
-
kW-mo/yr
|
- | - | - | $851 | - | |
| 07 | 2.7124: Make a practice of turning off lights when not needed | $273 | - |
$208
6,741
kWh
|
$36
-
kW-mo/yr
|
- | - | - | $29 | - | |
| 08 | 2.1232: Keep boiler tubes clean | $1,431 | $1,500 | - | - | - |
$1,431
-
MMBtu
|
- | - | - | |
| 09 | 3.4151: Minimize water usage | $1,020 | - | - | - | - | - |
$1,020
-
Tgal
|
- | - | |
| 10 | 3.4151: Minimize water usage | $275 | - | - | - | - | - |
$275
-
Tgal
|
- | - | |
| TOTAL RECOMMENDED | $133,907 | $699,201 |
$7,759
248,241
kWh
|
$1,758
-
kW-mo/yr
|
$8,062 |
$1,431
-
MMBtu
|
$1,295
-
Tgal
|
$880 | $112,722 | ||
| TOTAL IMPLEMENTED | $6,649 | $20,064 |
$5,332
170,574
kWh
|
$1,288
-
kW-mo/yr
|
- | - | - | $29 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs