Assessment Year | 1997 |
---|---|
Principal Product | Corrugated Boxes |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 105 |
Plant Area |
200,000
ft2
|
Annual Production | 865,000,000
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $143,265 | 4,128,664 |
kWh
|
$0.035 |
Electricity Demand | $40,182 | 9,216 |
kW-mo/yr
|
$4.36 |
Electricity Fees | $2,049 | - |
|
- |
Natural Gas | $72,946 | 11,060 |
MMBtu
|
$6.60 |
LPG | $22,043 | 2,896 |
MMBtu
|
$7.61 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,511 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,817 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,780 | $500 | - | - | - |
$1,780
-
MMBtu
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $7,037 | $9,611 |
$5,834
177,902
kWh
|
$1,203
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,504 | $7,050 |
$2,080
63,306
kWh
|
$424
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4322: Use or replace with energy efficient substitutes | $3,760 | $18,000 | - | - | - |
$3,760
-
MMBtu
|
- | - | |
05 | 3.4114: Replace city water with recycled water via cooling tower | $17,480 | $2,870 |
$(-410.0)
(-12,603)
kWh
|
$(-110.0)
-
kW-mo/yr
|
- | - | - |
$18,000
-
Tgal
|
|
06 | 2.1332: Convert combustion equipment to burn natural gas | $10,600 | $81,640 |
$(-2,500.0)
(-76,788)
kWh
|
$(-700.0)
-
kW-mo/yr
|
- |
$(-8,200.0)
-
MMBtu
|
$22,000
-
MMBtu
|
- | |
07 | 2.3212: Optimize plant power factor | $1,350 | $3,375 | - | - | $1,350 | - | - | - | |
TOTAL RECOMMENDED | $44,511 | $123,046 |
$5,004
151,817
kWh
|
$817
-
kW-mo/yr
|
$1,350 |
$(-2,660.0)
-
MMBtu
|
$22,000
-
MMBtu
|
$18,000
-
Tgal
|
||
TOTAL IMPLEMENTED | $8,817 | $10,111 |
$5,834
177,902
kWh
|
$1,203
-
kW-mo/yr
|
- |
$1,780
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs