Assessment Year 1997
Principal Product liquid CO2, dry ice
NAICS
n/a
SIC 2813: Industrial Gases
Sales Range $1
M
to 5
M
# of Employees 6
Plant Area 10,000
ft2
Annual Production 70,000
ton
Production Hrs. Annual 8,760
hrs
Location (State) Washington

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $104,235 4,826,495
kWh
Electricity Demand $58,439 11,073
kW-mo/yr
Electricity Fees $363 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $544,830 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,930

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Other Liquid (non-haz) Savings Primary Raw Material Savings Primary Product Savings
01 2.4324: Replace hydraulic / pneumatic equipment with electric equipment $6,130 $32,400 - - $130
-
gal
$6,000 -
02 2.2615: Clean condenser tubes $1,270 $5,000 $1,270
57,444
kWh
- - - -
03 2.2621: Modify refrigeration system to operate at a lower pressure $5,140 - $5,140
232,708
kWh
- - - -
04 4.652: Replace existing equipment with more suitable substitutes $529,800 $65,000 $(-9,100.0)
(-412,075)
kWh
$(-9,100.0)
-
kW-mo/yr
- - $548,000
05 2.4133: Use most efficient type of electric motors $390 $1,390 $282
12,896
kWh
$108
-
kW-mo/yr
- - -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,100 $9,050 $1,500
68,288
kWh
$600
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $544,830 $112,840 $(-908.0)
(-40,739)
kWh
$(-8,392.0)
-
kW-mo/yr
$130
-
gal
$6,000 $548,000
TOTAL IMPLEMENTED $12,930 $38,790 $6,692
303,048
kWh
$108
-
kW-mo/yr
$130
-
gal
$6,000 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Other Liquid (non-haz) Savings Primary Raw Material Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs