Assessment Year | 1997 |
---|---|
Principal Product | liquid CO2, dry ice |
NAICS |
n/a
|
SIC | 2813: Industrial Gases |
Sales Range | $1 M to 5M |
# of Employees | 6 |
Plant Area |
10,000
ft2
|
Annual Production | 70,000
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $104,235 | 4,826,495 |
kWh
|
$0.022 |
Electricity Demand | $58,439 | 11,073 |
kW-mo/yr
|
$5.28 |
Electricity Fees | $363 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $544,830 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,930 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Primary Raw Material Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $6,130 | $32,400 | - | - |
$130
-
gal
|
$6,000 | - | |
02 | 2.2615: Clean condenser tubes | $1,270 | $5,000 |
$1,270
57,444
kWh
|
- | - | - | - | |
03 | 2.2621: Modify refrigeration system to operate at a lower pressure | $5,140 | - |
$5,140
232,708
kWh
|
- | - | - | - | |
04 | 4.652: Replace existing equipment with more suitable substitutes | $529,800 | $65,000 |
$(-9,100.0)
(-412,075)
kWh
|
$(-9,100.0)
-
kW-mo/yr
|
- | - | $548,000 | |
05 | 2.4133: Use most efficient type of electric motors | $390 | $1,390 |
$282
12,896
kWh
|
$108
-
kW-mo/yr
|
- | - | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,100 | $9,050 |
$1,500
68,288
kWh
|
$600
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $544,830 | $112,840 |
$(-908.0)
(-40,739)
kWh
|
$(-8,392.0)
-
kW-mo/yr
|
$130
-
gal
|
$6,000 | $548,000 | ||
TOTAL IMPLEMENTED | $12,930 | $38,790 |
$6,692
303,048
kWh
|
$108
-
kW-mo/yr
|
$130
-
gal
|
$6,000 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Primary Raw Material Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs