Assessment Year | 1996 |
---|---|
Principal Product | Woolen Textiles |
NAICS |
n/a
|
SIC | 2231: Broadwoven Fabric Mills, Wool (Including Dyeing and Finishing) |
Sales Range | $10 M to 50M |
# of Employees | 242 |
Plant Area |
308,521
ft2
|
Annual Production | 13,691
thousand feet
|
Production Hrs. Annual | 3,840
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $241,867 | 10,963,072 |
kWh
|
$0.022 |
Electricity Demand | $104,758 | 27,624 |
kW-mo/yr
|
$3.79 |
Natural Gas | $257,823 | 101,564 |
MMBtu
|
$2.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,448 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,682 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $10,758 | $29,409 |
$7,285
323,857
kWh
|
$3,473
-
kW-mo/yr
|
- | - | - | - | - | |
02 | 2.2621: Modify refrigeration system to operate at a lower pressure | $1,405 | $8,000 |
$1,405
62,427
kWh
|
- | - | - | - | - | - | |
03 | 3.3128: Utilize other methods to remove contaminants | $3,361 | $22,130 | - | - | - |
$1,618
-
lb
|
$820
-
lb
|
$902 |
$21
-
Tgal
|
|
04 | 2.1232: Keep boiler tubes clean | $6,924 | $59,280 | - | - |
$6,924
-
MMBtu
|
- | - | - | - | |
TOTAL RECOMMENDED | $22,448 | $118,819 |
$8,690
386,284
kWh
|
$3,473
-
kW-mo/yr
|
$6,924
-
MMBtu
|
$1,618
-
lb
|
$820
-
lb
|
$902 |
$21
-
Tgal
|
||
TOTAL IMPLEMENTED | $17,682 | $88,689 |
$7,285
323,857
kWh
|
$3,473
-
kW-mo/yr
|
$6,924
-
MMBtu
|
- | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs