| Assessment Year | 1995 |
|---|---|
| Principal Product | cast aluminum parts |
| NAICS |
n/a
|
| SIC | 3321: Gray and Ductile Iron Foundries |
| Sales Range | $10 M to 50M |
| # of Employees | 270 |
| Plant Area |
180,000
ft2
|
| Annual Production | 12,284,000
lb
|
| Production Hrs. Annual | 3,960
hrs
|
| Location (State) | Washington |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $238,761 | 4,978,898 |
kWh
|
$0.048 |
| Natural Gas | $310,427 | 103,463 |
MMBtu
|
$3.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $21,814 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,886 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7134: Use photocell controls | $1,475 | $656 |
$980
23,447
kWh
|
- | - | $495 | |
| 02 | 2.4133: Use most efficient type of electric motors | $3,140 | $6,366 |
$3,140
65,358
kWh
|
- | - | - | |
| 03 | 3.5311: Recover and reuse waste material | $2,660 | - | - | - |
$2,660
-
lb
|
- | |
| 04 | 3.5221: Recycle casting sand | $9,746 | $12,960 | - | - |
$9,746
-
lb
|
- | |
| 05 | 3.8141: Regenerate cleaning solvent on-site and reuse | $4,793 | $65,000 | - |
$4,793
-
gal
|
- | - | |
| TOTAL RECOMMENDED | $21,814 | $84,982 |
$4,120
88,805
kWh
|
$4,793
-
gal
|
$12,406
-
lb
|
$495 | ||
| TOTAL IMPLEMENTED | $12,886 | $19,326 |
$3,140
65,358
kWh
|
- |
$9,746
-
lb
|
- | ||