Assessment Year | 1994 |
---|---|
Principal Product | Tortillas, Corn Chips |
NAICS |
n/a
|
SIC | 2096: Potato Chips, Corn Chips, and Similar Snacks |
Sales Range | $10 M to 50M |
# of Employees | 147 |
Plant Area |
39,240
ft2
|
Annual Production | 20,600,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $73,053 | 1,947,538 |
kWh
|
$0.038 |
Natural Gas | $188,804 | 45,663 |
MMBtu
|
$4.13 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,094 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $971 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $9,806 | $32,000 |
$16,341
412,075
kWh
|
$(-6,535.0)
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $834 | $1,840 |
$834
26,377
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $137 | $317 |
$137
3,517
kWh
|
- | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $317 | $1,000 |
$317
11,723
kWh
|
- | |
TOTAL RECOMMENDED | $11,094 | $35,157 |
$17,629
453,692
kWh
|
$(-6,535.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $971 | $2,157 |
$971
29,894
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs