Assessment Year | 1994 |
---|---|
Principal Product | Plastic Jugs |
NAICS |
n/a
|
SIC | 3085: Plastics Bottles |
Sales Range | $1 M to 5M |
# of Employees | 27 |
Plant Area |
14,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 8,320
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $59,794 | 2,085,287 |
kWh
|
$0.029 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,150 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,751 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $897 | $2,000 |
$897
31,653
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $2,085 | $3,659 |
$2,085
72,098
kWh
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,724 | $6,475 |
$1,724
59,789
kWh
|
- | |
04 | 2.3212: Optimize plant power factor | $1,026 | $1,400 |
$1,026
-
kWh
|
- | |
05 | 2.2612: Use cooling tower water instead of refrigeration | $4,373 | $14,067 |
$4,373
194,607
kWh
|
- | |
06 | 2.2621: Modify refrigeration system to operate at a lower pressure | $845 | - |
$845
37,515
kWh
|
- | |
07 | 3.1192: Reduce scrap production | $7,200 | $16,420 | - |
$7,200
-
lb
|
|
TOTAL RECOMMENDED | $18,150 | $44,021 |
$10,950
395,662
kWh
|
$7,200
-
lb
|
||
TOTAL IMPLEMENTED | $12,751 | $28,554 |
$5,551
201,055
kWh
|
$7,200
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs