Assessment Year 1994
Principal Product Glass fiber paper
NAICS
n/a
SIC 2621: Paper Mills
Sales Range $5
M
to 10
M
# of Employees 20
Plant Area
n/a
Annual Production 5,000,000
lb
Production Hrs. Annual 4,992
hrs
Location (State) Oregon

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $97,808 4,609,613
kWh
Natural Gas $79,300 28,795
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $23,850 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7124: Make a practice of turning off lights when not needed $4,644 - $4,644
105,803
kWh
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $262 - $262
4,396
kWh
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,933 $1,000 $4,933
124,267
kWh
04 2.7142: Utilize higher efficiency lamps and/or ballasts $3,583 $3,107 $3,583
99,062
kWh
05 2.7142: Utilize higher efficiency lamps and/or ballasts $5,438 $12,877 $5,438
144,783
kWh
06 2.4133: Use most efficient type of electric motors $800 $1,671 $800
19,930
kWh
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $4,190 $14,200 $4,190
104,924
kWh
TOTAL RECOMMENDED $23,850 $32,855 $23,850
603,165
kWh
TOTAL IMPLEMENTED - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs