ITAC Assessment: OR0200
ITAC logo
ITAC Assessment: OR0200
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1994
Principal Product Battery Separator Sheet
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 104
Plant Area 31,440
ft2
Annual Production 0
units
Production Hrs. Annual 7,880
hrs
Location (State) Oregon

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $229,627 10,146,542
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $26,581 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,994

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.6218: Turn off equipment when not in use $2,345 $200 $2,345
61,547
kWh
02 2.7142: Utilize higher efficiency lamps and/or ballasts $1,787 $2,608 $1,787
48,066
kWh
03 2.4133: Use most efficient type of electric motors $10,207 $18,835 $10,207
264,361
kWh
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $8,009 $28,931 $8,009
213,072
kWh
05 2.2136: Install / repair insulation on steam lines $4,233 $2,254 $4,233
129,250
kWh
TOTAL RECOMMENDED $26,581 $52,828 $26,581
716,296
kWh
TOTAL IMPLEMENTED $11,994 $21,443 $11,994
312,427
kWh
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs