| Assessment Year | 1994 |
|---|---|
| Principal Product | Custom Shutters |
| NAICS |
n/a
|
| SIC | 2431: Millwork |
| Sales Range | $10 M to 50M |
| # of Employees | 132 |
| Plant Area |
n/a
|
| Annual Production | 2,000
thousand feet
|
| Production Hrs. Annual | 2,574
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $55,478 | 1,267,585 |
kWh
|
$0.044 |
| Natural Gas | $26,347 | 6,303 |
MMBtu
|
$4.18 |
| Fuel Oil #2 | $14,140 | 2,388 |
MMBtu
|
$5.92 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,803 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,803 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $2,311 | $3,000 |
$2,311
-
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $256 | $1,029 |
$256
5,275
kWh
|
- | |
| 03 | 2.7124: Make a practice of turning off lights when not needed | $2,465 | - |
$2,465
73,564
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $433 | $1,820 |
$433
4,103
kWh
|
- | |
| 05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $385 | $500 | - |
$385
-
MMBtu
|
|
| 06 | 2.5125: Size air handling grills/ duct/s coils to minimize air resistance | $953 | $39,794 |
$953
22,274
kWh
|
- | |
| TOTAL RECOMMENDED | $6,803 | $46,143 |
$6,418
105,216
kWh
|
$385
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $6,803 | $46,143 |
$6,418
105,216
kWh
|
$385
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs