Assessment Year | 1993 |
---|---|
Principal Product | PVC pipe |
NAICS |
n/a
|
SIC | 3084: Plastics Pipe |
Sales Range | $10 M to 50M |
# of Employees | 55 |
Plant Area |
40,000
ft2
|
Annual Production | 50,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $274,353 | 10,527,550 |
kWh
|
$0.026 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,929 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,650 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $154 | - |
$154
5,569
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $1,031 | $2,722 |
$1,031
38,101
kWh
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,279 | $6,675 |
$1,279
47,186
kWh
|
|
04 | 2.6218: Turn off equipment when not in use | $5,474 | - |
$5,474
272,274
kWh
|
|
05 | 2.2511: Insulate bare equipment | $9,991 | $10,187 |
$9,991
392,732
kWh
|
|
TOTAL RECOMMENDED | $17,929 | $19,584 |
$17,929
755,862
kWh
|
||
TOTAL IMPLEMENTED | $16,650 | $12,909 |
$16,650
708,676
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs