Assessment Year | 1993 |
---|---|
Principal Product | Veneer |
NAICS |
n/a
|
SIC | 2436: Softwood Veneer and Plywood |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
80,000
ft2
|
Annual Production | 52,000,000
thousand feet
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $171,243 | 5,075,029 |
kWh
|
$0.034 |
Wood | $76,300 | 47,960 |
MMBtu
|
$1.59 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,247 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,764 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Energy Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.2514: Cover open tanks | $3,192 | $1,900 | - |
$3,192
-
MMBtu
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,353 | $10,000 |
$11,353
312,134
kWh
|
- | - | |
03 | 2.4133: Use most efficient type of electric motors | $590 | $3,210 |
$590
19,637
kWh
|
- | - | |
04 | 2.3212: Optimize plant power factor | $9,034 | $7,500 |
$9,034
-
kWh
|
- | - | |
05 | 2.7124: Make a practice of turning off lights when not needed | $4,483 | - |
$3,415
189,625
kWh
|
- | $1,068 | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $595 | $1,752 |
$433
18,464
kWh
|
- | $162 | |
TOTAL RECOMMENDED | $29,247 | $24,362 |
$24,825
539,860
kWh
|
$3,192
-
MMBtu
|
$1,230 | ||
TOTAL IMPLEMENTED | $24,764 | $24,362 |
$21,410
350,235
kWh
|
$3,192
-
MMBtu
|
$162 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Other Energy Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs