| Assessment Year | 1990 |
|---|---|
| Principal Product | DOOR ENTRY COMPONENTS |
| NAICS |
n/a
|
| SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
| Sales Range | $10 M to 50M |
| # of Employees | 140 |
| Plant Area |
n/a
|
| Annual Production | 480,000
pieces
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $359,905 | 5,868,992 |
kWh
|
$0.061 |
| Natural Gas | $22,369 | 7,065 |
MMBtu
|
$3.17 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $55,036 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $48,229 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $39,907 | $25,000 |
$52,548
934,936
kWh
|
$(-12,641.0)
-
MMBtu
|
- | |
| 02 | 2.2437: Recover waste heat from equipment | $8,220 | $2,876 | - |
$8,220
-
MMBtu
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,356 | $19,970 |
$5,243
93,200
kWh
|
- | $1,113 | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $451 | $502 |
$451
7,913
kWh
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $102 | - |
$102
4,103
kWh
|
- | - | |
| TOTAL RECOMMENDED | $55,036 | $48,348 |
$58,344
1,040,152
kWh
|
$(-4,421.0)
-
MMBtu
|
$1,113 | ||
| TOTAL IMPLEMENTED | $48,229 | $27,876 |
$52,650
939,039
kWh
|
$(-4,421.0)
-
MMBtu
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs