Assessment Year | 1993 |
---|---|
Principal Product | Plastic Pipe |
NAICS |
n/a
|
SIC | 3084: Plastics Pipe |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 5,996
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $104,841 | 3,610,786 |
kWh
|
$0.029 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,951 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,009 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $8,571 | - |
$8,571
393,318
kWh
|
- | |
02 | 2.7124: Make a practice of turning off lights when not needed | $942 | $390 |
$676
24,912
kWh
|
$266 | |
03 | 2.7134: Use photocell controls | $192 | $132 |
$133
6,155
kWh
|
$59 | |
04 | 2.4133: Use most efficient type of electric motors | $246 | $929 |
$246
8,206
kWh
|
- | |
TOTAL RECOMMENDED | $9,951 | $1,451 |
$9,626
432,591
kWh
|
$325 | ||
TOTAL IMPLEMENTED | $9,009 | $1,061 |
$8,950
407,679
kWh
|
$59 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs