| Assessment Year | 1993 |
|---|---|
| Principal Product | Lumber |
| NAICS |
n/a
|
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
n/a
|
| Annual Production | 79
units
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $479,579 | 11,742,087 |
kWh
|
$0.041 |
| Wood | $309,660 | 547,860 |
MMBtu
|
$0.57 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $76,052 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $69,704 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Wood Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $899 | - |
$899
19,930
kWh
|
- | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $1,655 | $6,603 |
$1,655
38,101
kWh
|
- | - | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,033 | $6,075 |
$1,033
25,205
kWh
|
- | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,577 | $5,000 |
$3,577
94,666
kWh
|
- | - | |
| 05 | 2.3212: Optimize plant power factor | $6,348 | $13,500 |
$6,348
-
kWh
|
- | - | |
| 06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $28,236 | $1,000 | - |
$28,236
-
MMBtu
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,477 | $12,988 |
$6,864
168,230
kWh
|
- | $2,613 | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,890 | $6,756 |
$2,012
52,755
kWh
|
- | $878 | |
| 09 | 2.4131: Size electric motors for peak operating efficiency | $21,937 | $100,000 |
$21,937
669,109
kWh
|
- | - | |
| TOTAL RECOMMENDED | $76,052 | $151,922 |
$44,325
1,067,996
kWh
|
$28,236
-
MMBtu
|
$3,491 | ||
| TOTAL IMPLEMENTED | $69,704 | $138,422 |
$37,977
1,067,996
kWh
|
$28,236
-
MMBtu
|
$3,491 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Wood Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs