| Assessment Year | 2003 |
|---|---|
| Principal Product | Industrial Coatings & Paint |
| NAICS | 325510: Paint and Coating Manufacturing |
| SIC | 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products |
| Sales Range | $100 M to 500M |
| # of Employees | 290 |
| Plant Area |
195,800
ft2
|
| Annual Production | 4,500
Tgal
|
| Production Hrs. Annual | 5,976
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $668,317 | 11,947,238 |
kWh
|
$0.056 |
| Electricity Fees | $2,250 | - |
|
- |
| Natural Gas | $61,827 | 8,082 |
MMBtu
|
$7.65 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $40,138 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7224: Reduce space conditioning during non-working hours | $18,000 | $4,600 |
$18,000
255,000
kWh
|
- | |
| 02 | 2.7124: Make a practice of turning off lights when not needed | $12,000 | - |
$12,000
171,000
kWh
|
- | |
| 03 | 2.6218: Turn off equipment when not in use | $3,550 | - |
$3,550
50,690
kWh
|
- | |
| 04 | 2.6218: Turn off equipment when not in use | $3,050 | - | - |
$3,050
-
MMBtu
|
|
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,925 | $2,280 |
$1,925
27,500
kWh
|
- | |
| 06 | 2.6218: Turn off equipment when not in use | $1,613 | - |
$1,613
23,040
kWh
|
- | |
| TOTAL RECOMMENDED | $40,138 | $6,880 |
$37,088
527,230
kWh
|
$3,050
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs