| Assessment Year | 1992 |
|---|---|
| Principal Product | Frozen Yorurt |
| NAICS |
n/a
|
| SIC | 2023: Dry, Condensed, and Evaporated Dairy Products |
| Sales Range | $10 M to 50M |
| # of Employees | 34 |
| Plant Area |
n/a
|
| Annual Production | 10,700,000
lb
|
| Production Hrs. Annual | 3,965
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $85,612 | 2,298,359 |
kWh
|
$0.037 |
| Natural Gas | $14,778 | 3,768 |
MMBtu
|
$3.92 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,413 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,057 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2691: Shut off cooling if cold outside air will cool process | $4,045 | $500 |
$4,045
121,630
kWh
|
- | - | |
| 02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,788 | - | - |
$1,788
-
MMBtu
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,356 | - |
$850
22,860
kWh
|
- | $506 | |
| 04 | 2.3212: Optimize plant power factor | $1,074 | $2,250 |
$1,074
-
kWh
|
- | - | |
| 05 | 2.2691: Shut off cooling if cold outside air will cool process | $830 | - |
$830
24,912
kWh
|
- | - | |
| 06 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $320 | $824 |
$320
8,499
kWh
|
- | - | |
| TOTAL RECOMMENDED | $9,413 | $3,574 |
$7,119
177,901
kWh
|
$1,788
-
MMBtu
|
$506 | ||
| TOTAL IMPLEMENTED | $8,057 | $3,574 |
$6,269
155,041
kWh
|
$1,788
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs