Assessment Year | 1992 |
---|---|
Principal Product | Tempered Glass, Insulate |
NAICS |
n/a
|
SIC | 3211: Flat Glass |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
n/a
|
Annual Production | 8,900
thousand feet
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $280,912 | 5,447,831 |
kWh
|
$0.052 |
Natural Gas | $7,785 | 1,607 |
MMBtu
|
$4.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,472 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,172 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,055 | - |
$3,055
80,012
kWh
|
- | |
02 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $1,832 | $360 |
$682
11,723
kWh
|
$1,150 | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,260 | $4,000 |
$4,260
97,890
kWh
|
- | |
04 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $676 | $1,436 |
$676
14,068
kWh
|
- | |
05 | 2.4311: Recover mechanical energy | $300 | $850 |
$300
6,741
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $349 | - |
$375
7,327
kWh
|
$(-26.0) | |
TOTAL RECOMMENDED | $10,472 | $6,646 |
$9,348
217,761
kWh
|
$1,124 | ||
TOTAL IMPLEMENTED | $10,172 | $5,796 |
$9,048
211,020
kWh
|
$1,124 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs