| Assessment Year | 1992 |
|---|---|
| Principal Product | PLYWOOD |
| NAICS |
n/a
|
| SIC | 2436: Softwood Veneer and Plywood |
| Sales Range | $10 M to 50M |
| # of Employees | 210 |
| Plant Area |
n/a
|
| Annual Production | 14,000
thousand feet
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $586,723 | 13,439,918 |
kWh
|
$0.044 |
| Wood | $304,500 | 2,528,400 |
MMBtu
|
$0.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $59,398 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $59,398 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $15,315 | $9,000 |
$15,315
-
kWh
|
- | |
| 02 | 2.4239: Eliminate or reduce compressed air usage | $3,489 | $2,600 |
$3,489
116,647
kWh
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $37,810 | $34,000 |
$37,810
972,157
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,216 | $2,049 |
$2,461
63,306
kWh
|
$(-245.0) | |
| 05 | 2.4133: Use most efficient type of electric motors | $568 | $8,405 |
$568
11,723
kWh
|
- | |
| TOTAL RECOMMENDED | $59,398 | $56,054 |
$59,643
1,163,833
kWh
|
$(-245.0) | ||
| TOTAL IMPLEMENTED | $59,398 | $56,054 |
$59,643
1,163,833
kWh
|
$(-245.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs