| Assessment Year | 1992 |
|---|---|
| Principal Product | MARINE PORTALS |
| NAICS |
n/a
|
| SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
| Sales Range | $1 M to 5M |
| # of Employees | 39 |
| Plant Area |
n/a
|
| Annual Production | 3,300
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $35,512 | 556,565 |
kWh
|
$0.064 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $1,168 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,118 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.6124: Establish equipment maintenance schedule | $628 | $120 |
$628
21,102
kWh
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $287 | $300 |
$287
4,689
kWh
|
|
| 03 | 2.4323: Use optimum size and capacity equipment | $203 | $640 |
$203
6,741
kWh
|
|
| 04 | 2.4133: Use most efficient type of electric motors | $50 | $173 |
$50
586
kWh
|
|
| TOTAL RECOMMENDED | $1,168 | $1,233 |
$1,168
33,118
kWh
|
||
| TOTAL IMPLEMENTED | $1,118 | $1,060 |
$1,118
32,532
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs