Assessment Year | 1992 |
---|---|
Principal Product | EXERCISE MACHINES |
NAICS |
n/a
|
SIC | 3949: Sporting and Athletic Goods, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 180 |
Plant Area |
n/a
|
Annual Production | 38,400
pieces
|
Production Hrs. Annual | 2,400
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $109,206 | 2,034,584 |
kWh
|
$0.054 |
Natural Gas | $29,448 | 7,567 |
MMBtu
|
$3.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,020 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,372 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 3.4156: Use flow control valves on equipment to optimize water use | $648 | - |
$648
10,551
kWh
|
- | - | |
02 | 2.4239: Eliminate or reduce compressed air usage | $4,166 | $1,710 |
$4,166
79,426
kWh
|
- | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $450 | $700 |
$333
6,741
kWh
|
- | $117 | |
04 | 2.4133: Use most efficient type of electric motors | $135 | $2,510 |
$135
2,638
kWh
|
- | - | |
05 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $1,621 | $5,299 | - |
$1,621
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $7,020 | $10,219 |
$5,282
99,356
kWh
|
$1,621
-
MMBtu
|
$117 | ||
TOTAL IMPLEMENTED | $6,372 | $10,219 |
$4,634
88,805
kWh
|
$1,621
-
MMBtu
|
$117 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs