Assessment Year | 1991 |
---|---|
Principal Product | DIMENSIONAL LUMBER |
NAICS |
n/a
|
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
n/a
|
Annual Production | 25,000
thousand feet
|
Production Hrs. Annual | 3,920
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $472,830 | 7,711,606 |
kWh
|
$0.061 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $48,969 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $48,969 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.6232: Install set-back timers | $1,035 | - |
$868
20,516
kWh
|
$167 | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $117 | - |
$117
586
kWh
|
- | |
03 | 2.4239: Eliminate or reduce compressed air usage | $4,152 | $1,000 |
$4,152
97,597
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $35,000 | $30,500 |
$35,000
577,081
kWh
|
- | |
05 | 2.3212: Optimize plant power factor | $6,809 | $15,000 |
$6,809
-
kWh
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $1,637 | $3,882 |
$1,637
23,740
kWh
|
- | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $219 | $850 |
$219
3,517
kWh
|
- | |
TOTAL RECOMMENDED | $48,969 | $51,232 |
$48,802
723,037
kWh
|
$167 | ||
TOTAL IMPLEMENTED | $48,969 | $51,232 |
$48,802
723,037
kWh
|
$167 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs