| Assessment Year | 1991 |
|---|---|
| Principal Product | LAMINATED PINE PANELS |
| NAICS |
n/a
|
| SIC | 2431: Millwork |
| Sales Range | $1 M to 5M |
| # of Employees | 40 |
| Plant Area |
n/a
|
| Annual Production | 1,800,000
thousand feet
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $93,937 | 2,024,912 |
kWh
|
$0.046 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,355 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $20,355 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,899 | - |
$1,899
58,030
kWh
|
- | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $758 | - |
$758
15,533
kWh
|
- | |
| 03 | 2.6232: Install set-back timers | $651 | - |
$543
12,016
kWh
|
$108 | |
| 04 | 2.4311: Recover mechanical energy | $15,535 | $4,270 |
$15,535
334,994
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $545 | - |
$440
11,137
kWh
|
$105 | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $571 | $1,000 |
$571
12,896
kWh
|
- | |
| 07 | 2.4133: Use most efficient type of electric motors | $88 | $189 |
$88
1,758
kWh
|
- | |
| 08 | 2.3212: Optimize plant power factor | $308 | $750 |
$308
-
kWh
|
- | |
| TOTAL RECOMMENDED | $20,355 | $6,209 |
$20,142
446,364
kWh
|
$213 | ||
| TOTAL IMPLEMENTED | $20,355 | $6,209 |
$20,142
446,364
kWh
|
$213 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs