| Assessment Year | 1991 |
|---|---|
| Principal Product | WALL PANELING |
| NAICS |
n/a
|
| SIC | 2435: Hardwood Veneer and Plywood |
| Sales Range | $1 M to 5M |
| # of Employees | 20 |
| Plant Area |
n/a
|
| Annual Production | 17
thousand feet
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Washington |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $22,073 | 430,246 |
kWh
|
$0.051 |
| Natural Gas | $19,191 | 4,147 |
MMBtu
|
$4.63 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,876 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $24,876 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,687 | $4,200 |
$2,687
71,512
kWh
|
- | - | |
| 02 | 2.3212: Optimize plant power factor | $3,011 | $4,800 |
$3,011
-
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,873 | - |
$1,464
38,980
kWh
|
- | $1,409 | |
| 04 | 2.4133: Use most efficient type of electric motors | $181 | $691 |
$181
4,982
kWh
|
- | - | |
| 05 | 2.1321: Replace fossil fuel equipment with electrical equipment | $16,124 | - |
$(-3,067.0)
(-57,737)
kWh
|
$19,191
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $24,876 | $9,691 |
$4,276
57,737
kWh
|
$19,191
-
MMBtu
|
$1,409 | ||
| TOTAL IMPLEMENTED | $24,876 | $9,691 |
$4,276
57,737
kWh
|
$19,191
-
MMBtu
|
$1,409 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs