| Assessment Year | 1991 |
|---|---|
| Principal Product | STEEL CASTINGS |
| NAICS |
n/a
|
| SIC | 3325: Steel Foundries, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 30 |
| Plant Area |
n/a
|
| Annual Production | 2,308,361
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $79,182 | 1,588,511 |
kWh
|
$0.050 |
| Natural Gas | $28,374 | 6,132 |
MMBtu
|
$4.63 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,161 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6242: Minimize operation of equipment maintained in standby condition | $3,060 | $2,900 | - |
$3,060
-
MMBtu
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,938 | $3,000 |
$2,938
75,322
kWh
|
- | |
| 03 | 2.3212: Optimize plant power factor | $1,000 | $1,425 |
$1,000
-
kWh
|
- | |
| 04 | 2.4133: Use most efficient type of electric motors | $113 | $226 |
$113
2,931
kWh
|
- | |
| 05 | 2.2511: Insulate bare equipment | $50 | $1,095 |
$50
2,052
kWh
|
- | |
| TOTAL RECOMMENDED | $7,161 | $8,646 |
$4,101
80,305
kWh
|
$3,060
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs