Assessment Year | 1991 |
---|---|
Principal Product | INJECTION-MOLDED PLASTIC |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 147 |
Plant Area |
n/a
|
Annual Production | 3,800,000
lb
|
Production Hrs. Annual | 6,600
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $247,817 | 5,375,440 |
kWh
|
$0.046 |
Natural Gas | $15,201 | 2,961 |
MMBtu
|
$5.13 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,372 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,372 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,432 | - |
$1,432
31,067
kWh
|
- | |
02 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $2,838 | - |
$2,184
56,272
kWh
|
$654 | |
03 | 2.2511: Insulate bare equipment | $3,367 | $3,124 |
$3,367
72,978
kWh
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $383 | $919 |
$383
7,913
kWh
|
- | |
05 | 2.3212: Optimize plant power factor | $2,040 | $5,100 |
$2,040
-
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $312 | $1,177 |
$312
4,982
kWh
|
- | |
TOTAL RECOMMENDED | $10,372 | $10,320 |
$9,718
173,212
kWh
|
$654 | ||
TOTAL IMPLEMENTED | $10,372 | $10,320 |
$9,718
173,212
kWh
|
$654 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs