Assessment Year | 1991 |
---|---|
Principal Product | ALES |
NAICS |
n/a
|
SIC | 2082: Malt Beverages |
Sales Range | n/a |
# of Employees | 40 |
Plant Area |
n/a
|
Annual Production | 268
Tgal
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $10,350 | 212,192 |
kWh
|
$0.049 |
Natural Gas | $6,364 | 1,236 |
MMBtu
|
$5.15 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,904 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,662 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 3.4115: Recover and reuse cooling water | $2,203 | $2,100 |
$(-102.0)
(-2,345)
kWh
|
- | $2,305 | |
02 | 3.4113: Treat and reuse rinse waters | $1,242 | - | - | - | $1,242 | |
03 | 2.4133: Use most efficient type of electric motors | $24 | $23 |
$24
586
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $211 | $319 |
$211
1,465
kWh
|
- | - | |
05 | 3.4113: Treat and reuse rinse waters | $366 | - |
$320
8,206
kWh
|
- | $46 | |
06 | 2.2623: Minimize condenser cooling water temperature | $588 | $1,500 |
$588
10,551
kWh
|
- | - | |
07 | 2.2511: Insulate bare equipment | $55 | $234 | - |
$55
-
MMBtu
|
- | |
08 | 2.1233: Analyze flue gas for proper air/fuel ratio | $215 | $1,000 | - |
$215
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $4,904 | $5,176 |
$1,041
18,463
kWh
|
$270
-
MMBtu
|
$3,593 | ||
TOTAL IMPLEMENTED | $3,662 | $5,176 |
$1,041
18,463
kWh
|
$270
-
MMBtu
|
$2,351 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs