| Assessment Year | 1998 |
|---|---|
| Principal Product | custom protective packaging |
| NAICS |
n/a
|
| SIC | 3086: Plastics Foam Products |
| Sales Range | $5 M to 10M |
| # of Employees | 52 |
| Plant Area |
95,000
ft2
|
| Annual Production | 700,000
pieces
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $15,687 | 1,005,276 |
kWh
|
$0.016 |
| Electricity Demand | $32,954 | 2,963 |
kW-mo/yr
|
$11.12 |
| Natural Gas | $15,218 | 3,397 |
MMBtu
|
$4.48 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,448 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,428 | $8,036 |
$1,191
76,495
kWh
|
$4,237
-
kW-mo/yr
|
|
| 02 | 2.7122: Disconnect ballasts | $3,050 | $350 |
$660
41,911
kWh
|
$2,390
-
kW-mo/yr
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $470 | $50 |
$100
6,448
kWh
|
$370
-
kW-mo/yr
|
|
| 04 | 2.4322: Use or replace with energy efficient substitutes | $500 | $1,750 |
$110
7,034
kWh
|
$390
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $9,448 | $10,186 |
$2,061
131,888
kWh
|
$7,387
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs