| Assessment Year | 1994 |
|---|---|
| Principal Product | Starters, alternators, clutch assemblies, and water pumps |
| NAICS |
n/a
|
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $10 M to 50M |
| # of Employees | 300 |
| Plant Area |
90,000
ft2
|
| Annual Production | 950,000
pieces
|
| Production Hrs. Annual | 5,928
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $97,558 | 1,888,335 |
kWh
|
$0.052 |
| Natural Gas | $23,782 | 7,542 |
MMBtu
|
$3.15 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,228 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,517 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1114: Limit and control secondary combustion air in furnace | $1,839 | $2,500 | - |
$1,839
-
MMBtu
|
|
| 02 | 2.2437: Recover waste heat from equipment | $1,730 | $1,600 | - |
$1,730
-
MMBtu
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,310 | - | - |
$1,310
-
MMBtu
|
|
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $638 | - |
$638
12,309
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $711 | $2,806 |
$711
9,672
kWh
|
- | |
| TOTAL RECOMMENDED | $6,228 | $6,906 |
$1,349
21,981
kWh
|
$4,879
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $5,517 | $4,100 |
$638
12,309
kWh
|
$4,879
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs