| Assessment Year | 1990 |
|---|---|
| Principal Product | DUCTILE IRON CASTINGS |
| NAICS |
n/a
|
| SIC | 3321: Gray and Ductile Iron Foundries |
| Sales Range | $1 M to 5M |
| # of Employees | 35 |
| Plant Area |
n/a
|
| Annual Production | 4,000,000
lb
|
| Production Hrs. Annual | 4,875
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $118,610 | 2,269,344 |
kWh
|
$0.052 |
| Natural Gas | $24,704 | 6,156 |
MMBtu
|
$4.01 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $19,949 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,100 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,753 | $8,531 |
$2,951
76,202
kWh
|
- | $2,802 | |
| 02 | 2.2531: Re-size charging openings or add movable cover or door | $14,100 | $5,000 | - |
$14,100
-
MMBtu
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $96 | $181 |
$96
2,052
kWh
|
- | - | |
| TOTAL RECOMMENDED | $19,949 | $13,712 |
$3,047
78,254
kWh
|
$14,100
-
MMBtu
|
$2,802 | ||
| TOTAL IMPLEMENTED | $14,100 | $5,000 | - |
$14,100
-
MMBtu
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs