Assessment Year | 1990 |
---|---|
Principal Product | COOKIES |
NAICS |
n/a
|
SIC | 2052: Cookies and Crackers |
Sales Range | $10 M to 50M |
# of Employees | 98 |
Plant Area |
n/a
|
Annual Production | 16,000,000
lb
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $101,431 | 2,278,136 |
kWh
|
$0.045 |
Natural Gas | $59,637 | 15,505 |
MMBtu
|
$3.85 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,578 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.1221: Replace obsolete burners with more efficient ones | $1,964 | $2,000 | - |
$1,964
-
MMBtu
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $835 | $1,381 |
$1,271
28,429
kWh
|
- | $(-436.0) | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,827 | $3,000 |
$1,827
28,429
kWh
|
- | - | |
04 | 2.4133: Use most efficient type of electric motors | $194 | $330 |
$194
4,103
kWh
|
- | - | |
05 | 2.2414: Use waste heat from hot flue gases to preheat | $1,758 | $3,599 | - |
$1,758
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $6,578 | $10,310 |
$3,292
60,961
kWh
|
$3,722
-
MMBtu
|
$(-436.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs