Assessment Year | 1990 |
---|---|
Principal Product | DIMENSIONED LUMBER |
NAICS |
n/a
|
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $10 M to 50M |
# of Employees | 71 |
Plant Area |
n/a
|
Annual Production | 45,000
thousand feet
|
Production Hrs. Annual | 6,760
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $244,230 | 5,021,981 |
kWh
|
$0.049 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $50,569 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,496 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,850 | - |
$1,850
38,101
kWh
|
|
02 | 2.3212: Optimize plant power factor | $20,444 | $16,800 |
$20,444
-
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,646 | $5,000 |
$3,646
140,094
kWh
|
|
04 | 2.8114: Change rate schedules or other changes in utility service | $24,439 | $46,216 |
$24,439
-
kWh
|
|
05 | 2.4133: Use most efficient type of electric motors | $190 | $490 |
$190
5,275
kWh
|
|
TOTAL RECOMMENDED | $50,569 | $68,506 |
$50,569
183,470
kWh
|
||
TOTAL IMPLEMENTED | $5,496 | $5,000 |
$5,496
178,195
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs